Skip to main content

Key Features

Hydra THV
 

Recapturable

 
Supraflex Cruz
 

Hydra Aortic Valve

 
Outflow Low radial strength
Provides conformability to the shape of the aorta
Mid Frame High hoop strength
Ensures circular configuration of the bioprosthetic valve
Inflow High radial strength
Provides fixation to the native aortic annulus
Hydra
 

Marker location and significance

  1. Self-expanding TAVI device to have 2 rows of marker
    • First Markers are located at Node 1
    • Second Markers are located at Node 3
  2. First markers help
    • In precise implantation of the valve at the targeted implantation zone
    • To ascertain the depth of implant
  3. Second markers indicate
    • When the THV leaflets are going to get deployed
Hydra
Case Example
 
Hydra
 

Hydra AVDC(Aortic Valve Delivery Catheter)

*14F equivalent integrated sheath diameter for patients requiring 22 mm or 26 mm Hydra valve.

Bovine Pericardium

  • Made from single bovine pericardium
  • Bioprosthetic valve leaflets are supra-annular in position, provide superior hemodynamics by providing larger effective orifice area and lower pressure gradient
  • Supra-annular valve position helps to maintain circular shape of the bioprosthetic valve even if the native annulus shape is elliptical
  • Proprietary anti-calcification treatment
 
Supraflex Cruz
Supraflex Cruz
 

 

Clinical experience

Excellent Hemodynamics

Hydra CE Study (n=157) 1

Single digit valve gradient up to 1-year follow up
Larger effective orifice area (EOA) up to 1-year follow up
 
Mean aortic gradient
 
1. JACC:Cardiovascular Interventions Vol. 15, No. 1, 2022 Jan 10, https://doi.org/10.1016/j.jcin.2021.09.004
 

Ordering Information

Reference
Number
Size
HYDRA22 22 mm
HYDRA26 26 mm
HYDRA30 30 mm

References:

1.Hydra CE study- DOI:10.1016/J.JCIN.2021.09.004

Disclaimers: This product is intended for use by or under the directions of a physician. Prior to use, refer to the “Instructions for use” supplied with the product for indications, contraindications, side effects, suggested procedure warnings and precautions. As part of our continuous product development policy we reserve the right to change product specifications without prior notification.

The Hydra CE study data included here is based on the data published in JACC: Cardiovascular Interventions. JACC: Cardiovascular Interventions is a specialty journal of Journal of the American College of Cardiology (JACC) and is a copyright of ©2022 American College of Cardiology Foundation. JACC: Cardiovascular Interventions encompasses the entire field of interventional cardiovascular medicine, including coronary, structural, peripheral and cerebrovascular interventions.

Caution: Check the regulatory status of the device before distribution in area where CE marking is not the regulation in force. Illustrations are artist’s representation only and should not be considered as engineering drawings or photographs. This information does not replace medical advice from the doctor / physician. Graphics on file at Sahajanand Medical Technologies Limited. Hydra is manufactured by Vascular Innovations Co., Ltd. Thailand, an SMT group company, Hydra is a trademark of Vascular Innovations Co., Ltd. ©2022 Sahajanand Medical Technologies Limited - All Rights Reserved. Specifications are subject to modifications, revision and improvements.