Key Features
 
 
 
Uniform expansion with No Dog-bone Effect

Fluoroscopic evidence

 

Pipit NC inflated with some part inside & (distal) part outside the stent.

Pipit NC inflated in mid segment of the stent

Pipit NC inflated with some part inside & (proximal) part outside the stent.

 
 
*Disclaimer : Bench Test conducted on 3.5 mm Pipit NC Balloon under fluoroscopic guidance. Bench Test Data on SMT File. Bench test data may not be indicative of clinical performance.
 
 

Bench test

 

Pipit NC inflated with some part inside & (distal) part outside the stent.

Pipit NC inflated in mid segment of the stent.

Pipit NC inflated with some part inside & (proximal) part outside the stent.

Overexpansion of the stent achieved with Pipit NC at proximal segment

 
*Disclaimer : Bench Test conducted using Semi-compliant Balloon, Pipit NC and stent . Bench Test Data on SMT File. Bench test data may not be indicative of clinical performance.
 
 
Lowest peak track force* (N)
 
*Data on file. Bench test results may not necessarily be indicative of clinical performance. Test performed by and data on file at Sahajanand Medical Technologies Ltd. Testing performed on Pipit (PTCA Balloon Dilatation Catheter – Non-Compliant) 3.50mmX 15mm, NC Emerge (3.50mmX 15mm), Accuforce NC (3.50mmX 15mm), NC Trek (3.50mmX 15mm)
 
Best-in-class pushability*
 
 
Efficiency in transfer of Push Force from hub to tip (in %)
 
*Data on file. Bench test results may not necessarily be indicative of clinical performance. Test performed by and data on file at Sahajanand Medical Technologies Ltd. Testing performed on Pipit (PTCA Balloon Dilatation Catheter – Non-Compliant) 3.50mmX 15mm, NC Emerge (3.50mmX 15mm), Accuforce NC (3.50mmX 15mm), NC Trek (3.50mmX 15mm)
 
Low rewrap profile
 

Average Max force to Re-cross (N)

 

Best-in-class shape memory profile due to Multi-layered balloon material and Improved manufacturing process

 
 
Hydrophilic coating is applied on the folded balloon which leads to coated- uncoated balloon surface.
  • During the folded state, hydrophilic coating helps in trackability
  • During inflation, uncoated portion helps in anchoring the balloon and prevents slippage
 
*Data on file. Bench test results may not necessarily be indicative of clinical performance. Test performed by and data on file at Sahajanand Medical Technologies Ltd. Testing performed on Pipit (PTCA Balloon Dilatation Catheter – Non-Compliant) 3.50mmX 15mm, NC Emerge (3.50mmX 15mm), Accuforce NC (3.50mmX 15mm), NC Trek (3.50mmX 15mm)
Low tip entry profile (0.41 mm / 0.016")
 
 
 
Source: Product brochures / marketing collaterals of respective brands
 


 
Kink-resistant shaft

Proximal & distal shaft of balloon had no kinks or lumen collapse at turning sequence 1,2,3,4.

 
Wrap the catheter such that it covers half of the circumference
 
Technical Specifications
Balloon material Multi-layered polyamide
Balloon fold Tri-fold
Hydrophilic coating Selective hydrophilic coating at distal shaft including balloon tip.
Tip entry profile 0.016"(0.41 mm)
Shaft diameter Proximal 1.95F, Distal 2.6F
Catheter length 140 cm
Rapid exchange length 25 cm
Markers on the proximal shaft 90 cm & 100 cm
Maximum recommended guidewire 0.014" (0.36 mm)
Guide catheter compatibility 5F
Nominal pressure 12 atm
Rated burst pressure 20 atm (18 atm for 5 mm)
Compliance Chart
Pressure
[atm]
2.00
mm
2.25
mm
2.50
mm
2.75
mm
3.00
mm
3.25
mm
3.50
mm
3.75
mm
4.00
mm
4.25
mm
4.50
mm
5.00
mm
8 1.96 2.18 2.44 2.69 2.88 3.14 3.42 3.67 3.90 4.10 4.35 4.92
10 1.99 2.23 2.48 2.73 2.95 3.20 3.46 3.71 3.95 4.18 4.43 4.96
12 2.02 2.26 2.52 2.76 3.01 3.25 3.50 3.75 4.00 4.25 4.50 5.00
14 2.05 2.30 2.56 2.80 3.05 3.30 3.54 3.79 4.05 4.35 4.55 5.07
16 2.08 2.34 2.60 2.83 3.09 3.36 3.58 3.83 4.10 4.48 4.62 5.14
18 2.11 2.38 2.64 2.88 3.13 3.43 3.63 3.88 4.16 4.54 4.69 5.22
20 2.14 2.42 2.68 2.93 3.17 3.47 3.67 3.92 4.21 4.62 4.75 5.28
 
 
 
Size Matrix and Ordering Information
Pipit NC
SKUs#
Length (mm)
6 8 10 12 15 20 25 30
Diameter (mm)
2.00 FGNT200006 FGNT200008 FGNT200010 FGNT200012 FGNT200015 FGNT200020 FGNT200025 FGNT200030
2.25 FGNT225006 FGNT225008 FGNT225010 FGNT225012 FGNT225015 FGNT225020 FGNT225025 FGNT225030
2.50 FGNT250006 FGNT250008 FGNT250010 FGNT250012 FGNT250015 FGNT250020 FGNT250025 FGNT250030
2.75 FGNT275006 FGNT275008 FGNT275010 FGNT275012 FGNT275015 FGNT275020 FGNT275025 FGNT275030
3.00 FGNT300006 FGNT300008 FGNT300010 FGNT300012 FGNT300015 FGNT300020 FGNT300025 FGNT300030
3.25 FGNT325006 FGNT325008 FGNT325010 FGNT325012 FGNT325015 FGNT325020 FGNT325025 FGNT325030
3.50 FGNT350006 FGNT350008 FGNT350010 FGNT350012 FGNT350015 FGNT350020 FGNT350025 FGNT350030
3.75 FGNT375006 FGNT375008 FGNT375010 FGNT375012 FGNT375015 FGNT375020 FGNT375025 FGNT375030
4.00 FGNT400006 FGNT400008 FGNT400010 FGNT400012 FGNT400015 FGNT400020 FGNT400025 FGNT400030
4.50 FGNT450006 FGNT450008 FGNT450010 FGNT450012 FGNT450015 FGNT450020 FGNT450025 FGNT450030
5.00 FGNT500006 FGNT500008 FGNT500010 FGNT500012 FGNT500015 FGNT500020 FGNT500025 FGNT500030

#Data on file, Internal bench test at RBP, Fluoroscopic test & surveys.

#SKU- Stock Keeping unit

Disclaimer: Pipit NC is a trademark of SMT. Specifications are subject to modification, revision and improvement. Accuforce is a Trademark of Terumo Corporation, Emerge is a trademark of Boston Scientific, Pantera Leo is a trademark of Biotranik SE & Co. KG., NC Trek is a trademark of Abbott.

Instructions for Use(Multilanguage)