Uniform distribution of coating on balloon surface

SEM images of the coating on the surface

Low magnification
(200x)

High magnification
(1000x)

High magnification
(3000x)

Uniform coating surface of Peripherics

Competitor 1

Competitor 2

Competitor 3

Paclitaxel* concentration in arterial tissue up to 14 days

Semi-crystalline paclitaxel

Coating process

Coating on balloon

Paclitaxel drug load of 2 μg/mm2

Proprietary coating technology

  • Proprietary balloon design
  • Balloon material has been conceptualized to maximise force transmission
  • Balloon has been designed to maximise the drug transfer during inflation
  • Optimal adhesion of coating to balloon with minimal loss during transit to lesion
  • Desired wall apposition to enable effective and uniform drug delivery

Technical specifications

Catheter type OTW (BTK) OTW (SFA)
Recommended guide wire 0.018" 0.035"
Tip Soft and tapered Soft and tapered
Balloon markers Two radiopaque markers Two radiopaque markers
Usable length 150 cm 130 cm
Recommended introducer sheath 2-4 mm: 4 F 5-6 mm: 6 F & 7 mm: 7 F
Nominal pressure (NP) 10 atm 7 atm
Rated burst pressure (RBP) 14 atm 11 atm

Size matrix: 0.018” OTW (BTK)

Balloon Diameter
(mm)
Balloon Length (mm)
80 100 120 150
2.00        
2.50        
3.00        
4.00        

Size matrix: 0.035” OTW (SFA)

Balloon Diameter
(mm)
Balloon Length (mm)
100 120 150
5.00      
6.00      
7.00      

Colored Sizes are make to order

BTK- Below the Knee, OTW - Over the Wire, SFA - Superficial Femoral Artery, SEM- Scanning Electron Microscope, MIC - Minimum Inhibitory Concentration,

PTA - Percutaneous Transluminal Angioplasty

Caution: This product is intended for use by or under the direction of a physician. Prior to use, refer to the "Instructions for use" supplied with these devices for indications, contraindications, side effects, suggested procedure warnings and precautions. As a part of our continuous product development policy, we reserve the right to change product specifications without prior notification. Information contained herein is for distribution outside the USA & Japan.

*Tests performed by and data on file at Sahajanand Medical Technologies Limited (SMT). Illustrations are artist's representations only and should not be considered as engineering drawings or photographs. Photos on file at Sahajanand Medical Technologies Limited.

Peripherics is a trademark of Sahajanand Medical Technologies Limited (SMT). Peripherics is currently not approved by USFDA and is not available for sale in USA.

Disclaimer: © 2022 Sahajanand Medical Technologies Limited - All rights reserved. Specifications are subject to modification, revision and improvement.