Mean push force in Newton (N) for stents with 38 to 40mm length

Supraflex Cruz
Bench test results may not necessarily be indicative of clinical performance. Test performed by and data on file at Sahajanand Medical Technologies Ltd. Testing performed on Supraflex Cruz Stent System (2.50 x 40 mm) n=5, Ultimaster Stent System (2.5 x 38 mm) n=4, Orsiro Stent System (2.50 x 40 mm) n=5, Xience Sierra Stent System (2.5 x 38 mm) n=4, Xience Xpedition Stent System (2.5 x 38 mm) n=5, Resolute Onyx Stent System (2.5 x 38 mm) n=4, Synergy Stent System (2.5 x 38 mm) n=5. Catheter performance test measures average force to cross a challenging path model

Proprietary 'LDZ' link

Improves flexibility of the stent
Transmits 'Push force' with higher efficiency
Improves overall radial strength
Resists longitudinal compression
Supraflex Cruz Product Detail

Open-Cell Design

Better flexibility
Better side-branch access

Unique blend of hydrophilic-hydrophobic biodegradable polymers from the pioneers in the biodegradable polymer technologies.

Blend of biodegradable polymers
PLLA: Poly-L-lactide
Hydrophobic
PLCL: Poly L-Lactide-co-Caprolactone
Hydrophobic
PVP: Polyvinyl Pyrrolidone
Hydrophilic
Drug: Sirolimus
Drug dose: 1.4 μg/mm2
Supraflex CDR
Nearly 80% of drug is released within one month (initial burst). Remaining drug is programmed to get released for 3 months. Designed to cover the entire period of arterial wound healing in real-world patients.

Strut Cross section

Scanning Electron Microscopy (SEM)

Polymer coating is elastomeric which does not tear off while expansion of stent
No peeling, flaking, cracking of polymer
No webbing formation of polymer during the shelf life of the stent
Proprietary technology ensures complete coating at the outer and inner curves

OCT healing pattern of Supraflex Cruz

NIH: Neointimal hyperplasia
1.Abhyankar, A, Abizaid, A, Chamié, D, Patel, G.  SiBi optical coherence tomography study. Catheter Cardiovasc Interv. 2020; 1– 8. https://doi.org/10.1002/ccd.29371
2. Presented at EuroPCR 2019, 22 May 2019 12:15 - 13:15 Room 243 / Level 2

Extensive size range so that there is no compromise

Long lengths (44mm & 48mm) available.

 

 

Overexpansion limits


 

 

Supraflex Cruz is a trademark of Sahajanand Medical Technologies Ltd. or its affiliates. Specifications are subject to modification, revision and improvement.

BioFreedom and BioMatrix Alpha are trademarks of Biosensors International. Xience V, Xience Alpine, Xience Prime, Xience Xpedition and Xience Sierra are trademarks of the Abbott Group of Companies. Resolute Onyx is a trademark of Medtronic, Inc. or it's affiliates. Synergy is a trademark of Boston Scientific Corporation or its affiliates. Ultimaster is a trademark of Terumo Corporation. Orsiro is a trademark of Biotronik SE.